Please use this identifier to cite or link to this item:
http://repositoriosenaiba.fieb.org.br/handle/fieb/904
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Senna, Valter de | - |
dc.contributor.author | Pinheiro, Carlos Alberto Orge | - |
dc.date.accessioned | 2019-07-24T19:39:31Z | - |
dc.date.available | 2019-07-24T19:39:31Z | - |
dc.date.issued | 2018-06-12 | - |
dc.identifier.citation | PINHEIRO, Carlos Alberto Orge. Detecção automática de epilepsia através do modelo espectral singular multivariado. Orientador: Valter de Senna. 2018. 133 f. Tese (Doutorado em Modelagem Computacional e Tecnologia Industrial) – Centro Universitário SENAI CIMATEC, Salvador, 2018. | pt_BR |
dc.identifier.other | http://repositoriosenaiba.fieb.org.br/handle/fieb/728?mode=full | - |
dc.identifier.uri | http://repositoriosenaiba.fieb.org.br/handle/fieb/904 | - |
dc.description.abstract | Os neurofisiologistas, para detecção da epilepsia, dispõem de uma série de pesquisas cujas metodologias buscam tornar automática essa atividade trabalhosa e demorada. No entanto, os resultados das pesquisas são encorajadores apenas para o enfoque específico ou quando a metodologia é aplicada a um paciente em particular a partir dos seus padrões de epilepsia. Então, o principal problema desta pesquisa é tornar o enfoque geral ou, de outra forma, que possa ser utilizada numa população maior de pacientes, a partir de um padrão geral. Para isso, o modelo espectral singular multivariado foi aplicado aos registros de um banco de sinais de pacientes comprovadamente epilépticos, obtidos por eletrodos dispostos no couro cabeludo, cujo acesso ao banco de sinais é público e gratuito. Dado o enfoque geral, buscou-se identificar padrões gerais de epilepsia a partir do modelo espectral singular multivariado. Após a etapa de ajustes, necessária para identificação destes padrões gerais, arquivos de outros pacientes foram utilizados para verificar a capacidade da metodologia proposta em identificar o intervalo com epilepsia e sem epilepsia, levando em consideração a marcação feita pelos neurofisiologistas experientes como padrão adequado, com base nos índices de diagnóstico. Os resultados obtidos indicaram que a metodologia proposta nesta Tese é tão boa quanto as metodologias disponíveis na literatura cujo enfoque é geral. A pesquisa ao buscar identificar a existência de algum padrão que anteceda ou suceda o intervalo epiléptico verificou a captação em alguns pacientes dos efeitos das descargas elétricas após o intervalo com epilepsia. ABSTRACT: Neurophysiologists, for the detection of epilepsy, have a series of researches whose methodologies seek to make this laborious and time-consuming activity automatic. However, research results are encouraging only for the specific focus or when the methodology is applied to a particular patient based on their epilepsy patterns. So, the main problem of this research is to make the focus general or, in another way, that it can be used in a larger population of patients, from a general pattern. For this, the multivariate singular spectral model was applied to the records of a signal bank of patients with proven epilepsy, obtained by electrodes placed on the scalp, whose access to the signal bank is public and free. Given the general approach, we sought to identify general patterns of epilepsy from the multivariate singular spectral model. After the adjustment step, necessary to identify these general patterns, files from other patients were used to verify the ability of the proposed methodology to identify the interval with epilepsy and without epilepsy, taking into account the marking made by experienced neurophysiologists as an adequate pattern, with based on diagnostic indices. The results obtained indicated that the methodology proposed in this Thesis is as good as the methodologies available in the literature whose focus is general. The research, seeking to identify the existence of any pattern that precedes or succeeds the epileptic interval, verified the uptake in some patients of the effects of electrical discharges after the interval with epilepsy. | pt_BR |
dc.description.sponsorship | SENAI CIMATEC | pt_BR |
dc.language.iso | pt_BR | pt_BR |
dc.publisher | Centro Universitário SENAI CIMATEC | pt_BR |
dc.rights | acesso aberto | pt_BR |
dc.subject | Epilepsia | pt_BR |
dc.subject | Detecção automática | pt_BR |
dc.subject | Análise espectral multivariada | pt_BR |
dc.subject | Decomposição de sinais | pt_BR |
dc.title | Detecção automática de epilepsia através do modelo espectral singular multivariado | pt_BR |
dc.title.alternative | Automatic detection of epilepsy using multivariate singular spectral model | - |
dc.type | Tese | pt_BR |
dc.embargo.terms | aberto | pt_BR |
dc.publisher.country | brasil | pt_BR |
dc.publisher.departament | Departamento do MCTI | pt_BR |
dc.publisher.program | Programa de Pós-Graduação Stricto Sensu do Centro Universitário SENAI CIMATEC | pt_BR |
dc.publisher.initials | SENAI CIMATEC | pt_BR |
dc.subject.cnpq | Engenharias | pt_BR |
dc.contributor.referees | Moreira, Davidson Martins | - |
dc.contributor.referees | Lima, Ivan Costa da Cunha | - |
dc.contributor.referees | Silva, Marcone Lopes da | - |
dc.contributor.referees | Rodrigues, Paulo Jorge Canas | - |
Appears in Collections: | Teses de Doutorado (PPG MCTI) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Carlos Alberto Orge Pinheiro.pdf | TCCP / TESE MCTI / SENAI CIMATEC | 13.63 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.