Please use this identifier to cite or link to this item: http://repositoriosenaiba.fieb.org.br/handle/fieb/333
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSacramento Junior, Gessé do-
dc.contributor.authorSantos, Alex Álisson Bandeira-
dc.contributor.authorTofaneli, Luzia Aparecida-
dc.date.accessioned2016-07-08T14:20:41Z-
dc.date.issued2013-11-03-
dc.identifier.citationSACRAMENTO JR., Gessé do; SANTOS, Alex Álisson B.; TOFANELI, Luzia A. Energy balance and sizing of refrigeration cascade system of 4 stages of applied to liquefaction of petrochemical inputs using carbon dioxide (CO2) in one of stages. In: XXII INTERNATIONAL CONGRESS OF MECHANICALENGINEERING - COBEM 2013. Cusco, 2013.pt_BR
dc.identifier.urihttp://repositoriosenaiba.fieb.org.br/handle/fieb/333-
dc.descriptionp.6881-6886pt_BR
dc.description.abstractThis article aims to demonstrate a computer simulation that describes the operation of a system geared to liquefaction of inputs processed in the petrochemical industry through a cooling system that operates in cascade with one of the cryogenic circuits loaded with carbon dioxide (CO2) The idea of carrying one of the cryogenic circuits with CO 2 was motivated by the large potential availability of this gas in Brazil in the coming years, due to the discovery of large oil reserves located in the pre-salt layer. In this layer, CO 2 is combined with natural gas, also quite abundant, which led us to choose the gas itself for the liquefying process. The concept of energy balance in thermodynamic cycles was adopted, applying the 1st Law of Thermodynamics for Control Volumes to obtain performance results that can meet the operating conditions imposed and enable the operation of the equipment modeled in this article. The modeling and dimensioning of the system were made by using the software EES (Engineering Equation Solver), while the COP circuit was emphasized for evaluation of the system performance emphasize.pt_BR
dc.language.isoen_USpt_BR
dc.sourcehttp://www.abcm.org.br/anais/cobem/2013/PDF/1637.pdfpt_BR
dc.subjectIndustrial Refrigerationpt_BR
dc.subjectCarbon dioxidept_BR
dc.subjectEnergy balancept_BR
dc.titleEnergy balance and sizing of refrigeration cascade system of 4 stages of applied to liquefaction of petrochemical inputs using carbon dioxide (CO2) in one of stagespt_BR
dc.title.alternativeXXII INTERNATIONAL CONGRESS OF MECHANICALENGINEERING - COBEM 2013pt_BR
dc.typeProdução bibliográfica: Trabalhos publicados em anais de eventospt_BR
dc.description.localpubRibeirão Pretopt_BR
dc.embargo.termsabertopt_BR
dc.embargo.lift2016-07-09T14:20:41Z-
Appears in Collections:Artigos Publicados em Periódicos (PPG MCTI)

Files in This Item:
File Description SizeFormat 
Energy balance ....pdf344.01 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.